Electrical
Requirements
Warnlng: Improper connection of the
equipment grounding conductor can
result in a risk of electrical shock.
A 120 Volt. 60 Hr. AC only. 15 Ampere
fused electrlcal supply IS reqwed
[tlme-delay fuse or clrcult breaker IS
recommended] It IS recommended that
a separate clrcult sewing only this
appliance be provided DO NOT USE AN
EXTENSION CORD.
A wrung diagram IS Included in Merature
package. The wiring diagram 1s also
located behlnd the control panel
Recommended
Grounding
Method
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD
GROUNDING PRONG.
For your personal safety, this appliance
must be grounded This appliance IS
equipped with a power supply cord
haVlnQ 0 3-piO”Q grounding PfUQ To
mln~mlze possible shock hazard. the
cord must be plugged Into a mating 3-
prong Qroundlng type wall receptacle,
grounded I” accordance with the
National Electrical Code. ANSliNFPA
70-1984 ++ and local codes and
ordinances See Figure 1 If a mating wall
ECeDtaCle is not available It IS the
PerSOnal
responslblllty and
obllgationofihe customer
Temporary .
Grounding Method
tiNOr, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD
GROUNDING PRONG.
r
CPowell”PPlY cora
Electrical ground Is required on this
appliance
If changing and properly grounding
ihe wall receptacle IS impossible and
where local codes permit (consult vour
elecfrical inspecfor]. a tetiporary
adODtOr rnav be oluaaed Into the
existing 2-p&Q ~all~&eptacle to mate
with the &prong power supply cord.
If this is done, you must connect a
separate copper QrOUndlnQ we (No. 18
mInImum) lo a grounded cold water
pipe by means of a clamp and then to
the exiernal grounding connector screw
-
Uo nol
ground
10 a gas supply pipe,
Do not connect to electrical supply
until appliance IS permanently
grounded See Figure 2.
Grounded cold water pipe must
have metal continuity to electrlcai
ground and not be interrupted
by plastic. rubber or other electrical
insulating connectors such as
Now Start...
With wall oven in kitchen.
1
Remove racks and other parts
n
from inside oven
2
Remove shipping materials.
n
tape and protective film from
wall oven. Do Not remove cardboard
ShippIng base at this lime
Remove the
oven control
knob Remove the 2 screws that
attach the control panel to the oven
frame Move the control panel down
and forward Disconnect the plug from
the terminal block. Carefully place
control panel. screws and oven control
knob in a safe location.
If oven WI// be vented outsIde, remove
the flue cover and collar cap See back-
cover for Venting lnstallat~on Instructions.
6
Assemble the flwble connector
n
from the Qas supply pipe in this
order: manual shut-off valve, K” nipple,
%” adaDter. flexlbie connector. W’
adapt& and K” nipple
Flexible connector
Manual
Yz” adapter
YI” adapter
shut-ofl
5
w
Open door to first stop posItIon
and lift door upward and off hInQeS
valve
WARNING: THE REGULATOR IS DIE CAST
IF THE CONNECTION IS MADE TOO
TIGHT, IT WILL CRACK RESULTING IN A
GAS LEAK AND POSSIBLE FIRE OR
EXPLOSION.
7
Lift wall oven up to cabinet
W
cutoul. using the oven opening
as an area to grip. Thread flexible
connector through back of wall oven
Plug the electrical cord Into the
grounded outlet Discard cardboard
shlpping piece
PANEL B